{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.ai-analytics.org/api/v1/nhtsa/complaints/check?make=R-VISION","name":"R-VISION","_source":{"data_provider":"AI Analytics","data_provider_url":"https://api.ai-analytics.org","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www-odi.nhtsa.dot.gov/downloads/","generated_at":"2026-09-15T16:05:54.456Z"},"summary":{"total_complaints":5,"deaths":0,"injured":0,"fires":5},"top_components":[{"component_desc":"ELECTRICAL SYSTEM","n":2},{"component_desc":"SERVICE BRAKES","n":1},{"component_desc":"ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS","n":1},{"component_desc":"ELECTRICAL SYSTEM:WIRING","n":1}],"recent_complaints":[{"cmplid":"1685753","date_received":"2020-08-18","make":"R-VISION","model":"CONDOR","model_year":2003,"deaths":0,"injured":0,"fire":1,"crash":0,"component_desc":"SERVICE BRAKES","description":"TL* THE CONTACT OWNS A 2003 R-VISION CONDOR. THE CONTACT STATED THAT WHILE DRIVING ABOUT 50 MPH, DOWN STEEP HILL, THE BRAKES FAILED TO ENGAGE AND CAUGHT ON FIRE. THE BRAKE ICON ILLUMINATED. THE VEHICLE WAS PUT IN THE LOWEST GEAR AND WAS MANEUVERED TO AN AREA THAT WAS A LITTLE FLATTER, IN THE MIDDLE OF NOWHERE. THE VEHICLE WAS TOWED TO AN INDEPENDENT MECHANIC WHO STATED THAT THE BOSCH BRAKES WERE INCLUDED IN A RECALL. THE TECHNICIAN REPLACED THE BRAKES. THE CONTACT STATED THAT HE DID NOT RECEIVE A RECALL NOTIFICATION. THE DEALER WAS NOT CALLED. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE FAILURE MILEAGE WAS 16,230.","canonical_url":"https://api.ai-analytics.org/vehicle-complaint/1685753"},{"cmplid":"682671","date_received":"2008-08-12","make":"R-VISION","model":"TRAIL CRUISER","model_year":2004,"deaths":0,"injured":0,"fire":1,"crash":0,"component_desc":"ELECTRICAL SYSTEM","description":"TL*THE CONTACT OWNS A 2004 R-VISION TRAIL CRUISER TRAVEL TRAILER.  OVERNIGHT, THE FUSE BOX IN THE TRAILER EMITTED SPARKS.  IN THE MORNING, THE CONTACT SMELLED A BURNING ODOR AND OPENED THE TRAILER.  THERE WERE THICK CLOUDS OF SMOKE POURING OUT OF THE TRAILER, WHICH WAS A FIRE HAZARD.  THE TOP HALF OF THE FUSE BOX WAS ENTIRELY MELTED AND THE 12 VOLT PANEL WAS DESTROYED.  THE FAILURE MILEAGE WAS UNKNOWN.","canonical_url":"https://api.ai-analytics.org/vehicle-complaint/682671"},{"cmplid":"681966","date_received":"2008-08-07","make":"R-VISION","model":"TRAIL-SPORT","model_year":2008,"deaths":0,"injured":0,"fire":1,"crash":0,"component_desc":"ELECTRICAL SYSTEM","description":"TL*THE CONTACT OWNS A 2008 R-VISION TRAIL-SPORT CAMPER, MODEL 27QBSS.  THE CONTACT WAS OUT CAMPING FOR EIGHT DAYS AND THREE HOURS AFTER RETURNING HOME, THE CAMPER CAUGHT FIRE.  THE FIRE ORIGINATED UNDER THE STRUCTURE AND SPREAD TO THE MIDDLE OF THE CAMPER FLOOR.  THE GHOLSON VOLUNTEER FIRE DEPARTMENT INVESTIGATED THE FIRE AND CONCLUDED THAT THE FIRE WAS DUE TO AN ELECTRICAL FAILURE.  THE INSURANCE COMPANY INVESTIGATED THE FAILURE AND WILL NOTIFY THE MANUFACTURER.  THE FAILURE MILEAGE WAS UNAVAILABLE.","canonical_url":"https://api.ai-analytics.org/vehicle-complaint/681966"},{"cmplid":"564847","date_received":"2005-12-05","make":"R-VISION","model":"TRAIL BAY","model_year":2003,"deaths":0,"injured":0,"fire":1,"crash":0,"component_desc":"ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS","description":"DT:  THE CONTACT COMPLAINED ABOUT  PROBLEMS WITH  2003 R-VISION, MODEL 27FKSS TRAIL BAY. THE BREAKER BOX CAUGHT ON FIRE.  HE WAS ABLE TO EXTINGUISH THE FIRE.  THE BREAKER BOX NEEDED TO BE REPLACED, AND THERE WAS SMOKE DAMAGE TO THE SURROUNDING PANEL.  THE FIRE DEPARTMENT INSPECTED THE DAMAGE.  THEY BELIEVED WATER DRIPPED ON THE ELECTRICAL WIRES CAUSING THE FIRE.  THE DAMAGE HAS NOT BEEN REPAIRED.   ADDITIONALLY, THE FIRE EXTINGUISHER PROVIDED WITH THE VEHICLE WAS NOT THE APPROPRIATE TYPE.   *AK","canonical_url":"https://api.ai-analytics.org/vehicle-complaint/564847"},{"cmplid":"552427","date_received":"2005-09-01","make":"R-VISION","model":"TRAIL-LITE","model_year":2002,"deaths":0,"injured":0,"fire":1,"crash":0,"component_desc":"ELECTRICAL SYSTEM:WIRING","description":"WHILE PREPARING FOR A TRIP IN THE TRAILER, THE SMELL OF HOT ELECTRICAL WIRES WAS NOTED.  UPON SEARCHING FOR THE SOURCE OF THE SMELL, A FIRE WAS NOTED ON A PLASTIC (PVC) PIPE.  THE FIRE WAS EXTINGUISHED, THEN THE SOURCE OF THE HEAT WAS SEARCHED FOR.  OTHER MATERIALS WERE BURNED ON THE UNDERSIDE OF THE TRAILER.  AFTER MOVING SOME INSULATION AND OTHER MATERIALS AND SOOT, THE SOURCE OF THE FIRE WAS LOCATED.  THE CABLE RUNNING FROM THE BATTERY TO THE POWER CENTER WAS INSTALLED BETWEEN THE STEEL FLOOR FRAME AND THE WOODEN WALL FRAME.  APPARENTLY THE CABLE WAS PINCHED BETWEEN THE TWO FRAMES AND EVENTUALLY THE INSULATION WORE AWAY CAUSING AN ELECTRICAL SHORT.  THE DAMAGE HAS NOT BEEN CORRECTED AS OF 9/1/2005.  *NM","canonical_url":"https://api.ai-analytics.org/vehicle-complaint/552427"}]}