{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=OWENS%20ILLINOIS","name":"OWENS ILLINOIS","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-10-04T05:18:47.561Z"},"summary":{"total_severe_injuries":8,"amputations":5,"hospitalizations":4,"eye_losses":0},"top_body_parts":[{"body_part_title":"Finger(s), fingernail(s), n.e.c.","n":3},{"body_part_title":"Finger(s), fingernail(s), unspecified","n":2},{"body_part_title":"Hand(s), except finger(s)","n":1},{"body_part_title":"Fingertip(s)","n":1},{"body_part_title":"BODY SYSTEMS","n":1}],"recent_reports":[{"id":"2017099392","event_date":"9/29/2017","employer":"Owens - Illinois","city":"AUBURN","state":"NEW YORK","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery, unspecified","final_narrative":"An employees thumb tip was crushed and amputated in a machine.","canonical_url":"https://api.morvs.ai/workplace-injury/2017099392"},{"id":"2017099223","event_date":"9/26/2017","employer":"Owens Illinois, Inc.","city":"BROCKPORT","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Multiple effects of heat and light","body_part_title":"BODY SYSTEMS","event_title":"Exposure to environmental heat","final_narrative":"While working on the take-out arm of a glass forming machine, an employee became lightheaded, requiring hospitalization for dehydration and heat exhaustion.","canonical_url":"https://api.morvs.ai/workplace-injury/2017099223"},{"id":"2016076811","event_date":"7/26/2016","employer":"Owens-Illinois Glass","city":"PERRYSBURG","state":"OHIO","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was conducting maintenance on the HVAC when the wind caused the HVAC blades to unexpectedly move, amputating the intermediate phalange of the employee's right middle finger and the distal phalange of the right ring finger.","canonical_url":"https://api.morvs.ai/workplace-injury/2016076811"},{"id":"2021119433","event_date":"11/1/2021","employer":"Owens-Illinois","city":"WACO","state":"TEXAS","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Caught in running equipment or machinery, unspecified","final_narrative":"An employee was taking blank temperatures on a forming machine. As the employee inserted blank temperature probes into the blanks, their right index finger was pinched between the blank arm and the operating shaft. The finger was degloved to the first knuckle, and was later medically amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2021119433"},{"id":"20181010342","event_date":"10/5/2018","employer":"Owens Illinois","city":"STREATOR","state":"ILLINOIS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Struck by object falling from vehicle or machinery-other than vehicle part","final_narrative":"An employee was troubleshooting a new machine. A piece of metal fell from the machine and struck the employee's left middle finger, causing an amputation.","canonical_url":"https://api.morvs.ai/workplace-injury/20181010342"},{"id":"2015108164","event_date":"10/30/2015","employer":"Owens Illinois","city":"ATLANTA","state":"GEORGIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was taking the temperature of a mold inside a foaming machine and dropped the temperature probe. As the employee tried to retrieve the probe, the left index finger was amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2015108164"},{"id":"2015108146","event_date":"10/21/2015","employer":"Owens Illinois Glass","city":"WACO","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Avulsions, enucleations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was making an adjustment to a pneumatic strapper head that was energized. Pneumatic pressure kicked back pinching the employee's right ring finger between the adjustment tool and the metal plating causing a loss of soft tissue (no bone) requiring surgical repair.","canonical_url":"https://api.morvs.ai/workplace-injury/2015108146"},{"id":"2018010504","event_date":"1/16/2018","employer":"OWENS ILLINOIS","city":"ZANESVILLE","state":"OHIO","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Cuts, lacerations","body_part_title":"Hand(s), except finger(s)","event_title":"Struck against moving part of machinery or equipment","final_narrative":"On January 16, 2018, an employee was operating a table saw to cut wood when the blade lacerated his right-hand palm, requiring surgery. The saw was unguarded at the time.","canonical_url":"https://api.morvs.ai/workplace-injury/2018010504"}]}