{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=Poly-America%2C%20L.P.","name":"Poly-America, L.P.","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-10-03T09:28:00.406Z"},"summary":{"total_severe_injuries":14,"amputations":5,"hospitalizations":10,"eye_losses":0},"top_body_parts":[{"body_part_title":"Fingertip(s)","n":4},{"body_part_title":"Finger(s), fingernail(s), unspecified","n":2},{"body_part_title":"Trunk and other upper extremities","n":1},{"body_part_title":"Leg(s), unspecified","n":1},{"body_part_title":"Hand(s), unspecified","n":1},{"body_part_title":"Hand(s), finger(s)  unspecified","n":1},{"body_part_title":"Hand(s) and finger(s)","n":1},{"body_part_title":"Brain","n":1}],"recent_reports":[{"id":"2016098643","event_date":"9/13/2016","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Injured by slipping or swinging object held by injured worker","final_narrative":"An employee was using a date stamper on boxes when her left index finger was caught in the date stamper mechanism, amputating her fingertip.","canonical_url":"https://api.morvs.ai/workplace-injury/2016098643"},{"id":"2016088065","event_date":"8/26/2016","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery, n.e.c.","final_narrative":"An employee was starting up a bagging machine and suffered a fingertip amputation.","canonical_url":"https://api.morvs.ai/workplace-injury/2016088065"},{"id":"2021076083","event_date":"7/23/2021","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Intracranial injuries, unspecified","body_part_title":"Brain","event_title":"Fall on same level due to slipping","final_narrative":"An employee slipped on some plastic banding and fell, suffering a head injury.","canonical_url":"https://api.morvs.ai/workplace-injury/2021076083"},{"id":"2023065615","event_date":"6/24/2023","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Effects of heat and light, unspecified","body_part_title":"BODY SYSTEMS","event_title":"Exposure to environmental heat","final_narrative":"An employee was packing rolls of plastic trash bags when he became ill and developed breathing problems. He was hospitalized for heat stress.","canonical_url":"https://api.morvs.ai/workplace-injury/2023065615"},{"id":"2016065276","event_date":"6/14/2016","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Struck by falling object or equipment, n.e.c.","final_narrative":"An employee was emptying a box of scrap plastic onto a sorting table and suffered a broken little finger when trying to prevent plastic from sliding off the table.","canonical_url":"https://api.morvs.ai/workplace-injury/2016065276"},{"id":"2019054496","event_date":"5/3/2019","employer":"POLY-AMERICA, L.P.","city":"MONT BELVIEU","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Multiple traumatic injuries and disorders, unspecified","body_part_title":"Hand(s) and finger(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was repairing the speed sensor alignment on a plastic grinder's out-feed blower. A pipe wrench on the blower shaft spun around and caught his hand between the wrench and the blower housing resulting in lacerations to his hand and a crushing injury to his middle finger.","canonical_url":"https://api.morvs.ai/workplace-injury/2019054496"},{"id":"2023032053","event_date":"3/6/2023","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Soreness, pain, hurt-nonspecified injury","body_part_title":"Leg(s), unspecified","event_title":"Pedestrian struck by forward-moving vehicle in nonroadway area","final_narrative":"An employee was coming back from their break and crossing a path when they were struck by a forklift, resulting in a right leg injury that required hospitalization.","canonical_url":"https://api.morvs.ai/workplace-injury/2023032053"},{"id":"20231211257","event_date":"12/10/2023","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Cuts, lacerations","body_part_title":"Hand(s), unspecified","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was monitoring and operating a converting machine. As the employee was removing a roll of plastic trash bags that was stuck on a shaft, the machine's push-off device/plate lacerated the top of the employee's right hand.","canonical_url":"https://api.morvs.ai/workplace-injury/20231211257"},{"id":"2022119829","event_date":"11/8/2022","employer":"POLY-AMERICA, L.P.","city":"MONT BELVIEU","state":"TEXAS","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Contact with objects and equipment, unspecified","final_narrative":"An employee was assisting to empty a feeder. When rotating the sleeve, the employee's finger made contact with the rotating helix, resulting in an amputation to the right index finger.","canonical_url":"https://api.morvs.ai/workplace-injury/2022119829"},{"id":"20241110721","event_date":"11/18/2024","employer":"POLY-AMERICA, L.P.","city":"MONT BELVIEU","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Thermal burns  degree unspecified","body_part_title":"Trunk and other upper extremities","event_title":"Contact with hot objects or substances","final_narrative":"An employee was walking past a control panel when a bolt broke and 144-degree water sprayed them, resulting in burns to their chest, torso, and right arm and hand.","canonical_url":"https://api.morvs.ai/workplace-injury/20241110721"},{"id":"20191010715","event_date":"10/14/2019","employer":"POLY-AMERICA, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in or compressed by equipment or objects, unspecified","final_narrative":"An employee was clearing clogged material on an auger when his finger was caught between the auger and the auger housing, resulting in a right index fingertip amputation.","canonical_url":"https://api.morvs.ai/workplace-injury/20191010715"},{"id":"2024010216","event_date":"1/9/2024","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Hand(s), finger(s)  unspecified","event_title":"Struck by running powered equipment  during maintenance, cleaning, testing","final_narrative":"An employee was performing maintenance on a turret. They removed a panel to view the turret's bearings, and their left hand was pulled into the rotating turret, resulting in a fracture.","canonical_url":"https://api.morvs.ai/workplace-injury/2024010216"},{"id":"2021010521","event_date":"1/20/2021","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was stacking plastic bags and staging them to lift off a transfer table. When the employee lifted a stack of bags, her right pinky finger was pinched by a transfer belt, resulting in a partial amputation of her fingertip (without bone loss).","canonical_url":"https://api.morvs.ai/workplace-injury/2021010521"},{"id":"2016010489","event_date":"1/18/2016","employer":"Poly-America, L.P.","city":"GRAND PRAIRIE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Arm(s), unspecified","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was working on a lathe when his sleeve got caught in the rotating shaft. His left arm was pulled in and broken.","canonical_url":"https://api.morvs.ai/workplace-injury/2016010489"}]}