{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.ai-analytics.org/api/v1/osha/sir/check?name=TechnipFMC","name":"TechnipFMC","_source":{"data_provider":"AI Analytics","data_provider_url":"https://api.ai-analytics.org","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-09-04T18:38:23.234Z"},"summary":{"total_severe_injuries":11,"amputations":6,"hospitalizations":5,"eye_losses":0},"top_body_parts":[{"body_part_title":"Fingertip(s)","n":3},{"body_part_title":"Finger(s), fingernail(s), n.e.c.","n":3},{"body_part_title":"Toes(s), toenail(s)","n":1},{"body_part_title":"Thigh(s)","n":1},{"body_part_title":"Hand(s), except finger(s)","n":1},{"body_part_title":"Finger or thumb tip(s), nail(s)","n":1},{"body_part_title":"Exterior and musculoskeletal structures of the neck","n":1}],"recent_reports":[{"id":"2024087506","event_date":"8/15/2024","employer":"TechnipFMC","city":"HOUSTON","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Exterior and musculoskeletal structures of the neck","event_title":"Fall on same level  n.e.c.","final_narrative":"An employee was function testing a flushing unit when the unit failed and the access panel was forced open as the filter housing ejected upward from the unit. The access panel struck the employee on his hard hat and he fell backward onto concrete, resulting in a fracture to their C1 vertebra.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2024087506"},{"id":"2019088265","event_date":"8/12/2019","employer":"TechnipFMC, PLC","city":"ODESSA","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was assembling a valve when the parts slid together, crushing his left index finger and resulting in a finger amputation.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2019088265"},{"id":"2023065739","event_date":"6/28/2023","employer":"TechnipFMC","city":"KILLDEER","state":"NORTH DAKOTA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Crushing injuries","body_part_title":"Fingertip(s)","event_title":"Struck by falling object or equipment, unspecified","final_narrative":"An employee was hooking up a hose when the hose fell and crushed their fingertip.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2023065739"},{"id":"2021065002","event_date":"6/19/2021","employer":"TechnipFMC","city":"KILLDEER","state":"NORTH DAKOTA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Thigh(s)","event_title":"Contact with objects and equipment, unspecified","final_narrative":"An employee was connecting a 4-inch metal flex hose to a connection point. The hose slipped off the connection point and pinched the employee's right leg against a wellhead isolation valve, causing an open fracture to the femur.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2021065002"},{"id":"2018055178","event_date":"5/26/2018","employer":"TechnipFMC","city":"WATFORD CITY","state":"NORTH DAKOTA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was unscrewing a 2-inch iron elbow from a 2-inch iron straight pipe. The pipe shifted, and his left index finger was pinched between the elbow and the pipe. His left index finger was amputated at the first knuckle.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2018055178"},{"id":"2018043521","event_date":"4/12/2018","employer":"TechnipFMC","city":"SAN ANTONIO","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Injured by slipping or swinging object held by injured worker","final_narrative":"An employee was disassembling a butterfly valve and using a ball-peen hammer to remove the seal insert when the hammer struck and amputated the employee's left pinky fingertip.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2018043521"},{"id":"20171110863","event_date":"11/11/2017","employer":"TechnipFMC","city":"STANTON","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Injured by slipping or swinging object held by injured worker","final_narrative":"An employee was removing a flange from a client's oil/gas well with a hydraulic torque wrench. While the employee was placing the torque wrench on the nut, the employee's finger was in a pinch point between the torque wrench and nut. The employee then inadvertently stepped on the controller, which activated the torque wrench, amputating the employee's right index fingertip and nail.","canonical_url":"https://api.ai-analytics.org/workplace-injury/20171110863"},{"id":"2021109059","event_date":"10/21/2021","employer":"TechnipFMC, PLC","city":"ODESSA","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Toes(s), toenail(s)","event_title":"Struck by falling object or equipment, n.e.c.","final_narrative":"An employee was assembling a stem packing nut into a valve body. As the employee was tightening the nut, the valve and flow cross assembly rolled off its wooden blocks onto his right foot (about 6 inches below). His third, fourth, and fifth toes were broken.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2021109059"},{"id":"2022010883","event_date":"1/29/2022","employer":"TechnipFMC","city":"STEPHENVILLE","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"Two employees were working together to rotate a wellhead adapter. Employee 1 was using an overhead hoist and lifting strap to lift one side of the adapter and place it on its opposite side. Employee 1 began to lower the adapter down, and Employee 2's left middle finger was caught in a pinch point between the lifting strap and the part, resulting in a fingertip amputation.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2022010883"},{"id":"2025010726","event_date":"1/23/2025","employer":"TechnipFMC","city":"HALLIDAY","state":"NORTH DAKOTA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations, avulsions, enucleations  unspecified","body_part_title":"Finger or thumb tip(s), nail(s)","event_title":"Struck by running powered equipment  during maintenance, cleaning, testing","final_narrative":"An employee was rigging chains to a crane to lift a zipper assembly. While the employee was taking slack out, their right index finger was caught between a chain and the zipper assembly. The fingertip was amputated to the nailbed.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2025010726"},{"id":"2024010305","event_date":"1/12/2024","employer":"TechnipFMC","city":"CHARLEROI","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Cuts, lacerations, punctures without injury to internal structures","body_part_title":"Hand(s), except finger(s)","event_title":"Struck by discharged object or substance","final_narrative":"An employee was using a hydraulic-pressured torque wrench to torque a bonnet connection on a valve when the elbow section of the torque head released pressure, resulting in a pressure cut/injection into the employee's left palm.","canonical_url":"https://api.ai-analytics.org/workplace-injury/2024010305"}]}