# NTSB Incident CHI95IA066
> **BEECH 1900D** · 1995-01-12 · WILLISTON, ND, USA · NONE
## Event
- **NTSB number:** CHI95IA066
- **Event ID:** 20001207X02832
- **Type:** Incident
- **Date:** 1995-01-12
- **Location:** WILLISTON, ND, USA
## Injuries
- **Highest injury:** NONE
- **Fatal:** 0
- **Serious:** 0
- **Minor:** 0
- **Uninjured:** 6
- **Total aboard:** 6
## Aircraft
- **Make:** BEECH
- **Model:** 1900D
- **Registration:** N118UX
- **FAR Part:** 135
- **Engines:** 2
- **Damage:** MINR
## Conditions
- **Light:** DAYL
- **Weather:** VMC
## Probable cause

the improper installation and inadequate quality assurance inspection of the elevator trim cable during original manufacture, which resulted in fraying and failure of the cable prior to the first routine scheduled inspection of the system.

---