← FAA Federal Register actions

Airworthiness Directives; McDonnell Douglas Model DC-10-10, -10F, -15, -30, -30F (KC-10A and KDC-10), -40, and -40F Series Airplanes; and Model MD-10-10F and MD-10-30F Series Airplanes

airworthiness · Rule · Final rule. · Published 2002-04-02 · Effective 2002-05-07 · 67 FR 15472

Document

Document number
02-7413
Federal Register citation
67 FR 15472
Type
Rule
Action
Final rule.
Category
airworthiness
Publication date
2002-04-02
Effective date
2002-05-07
FAA docket
Docket No. 2001-NM-121-AD

Abstract

This amendment adopts a new airworthiness directive (AD) applicable to certain McDonnell Douglas Model DC-10-10, -10F, -15, -30, -30F (KC-10A and KDC-10), -40, and -40F series airplanes; and Model MD- 10-10F and MD-10-30F series airplanes. This action requires an inspection of the parallel power feeder cables of the number 2 generator for chafing or structure damage; repositioning of the cables; and repair, if necessary. This action is necessary to prevent wire chafing of the parallel power feeder cables of the number 2 generator, which, if not corrected, could result in electrical arcing and damage to adjacent structure, and consequent smoke and/or fire in the aft door panel area. This action is intended to address the identified unsafe condition.

Source

Authoritative
Federal Register document
Machine