# Airworthiness Directives; Fokker Model F.28 Mark 0100 Airplanes
> **Rule** · Final rule. · Published 2005-06-15 · Effective 2005-07-20 · 70 FR 34642
## Document
- **Document number:** 05-11694
- **Category:** airworthiness
- **Manufacturer:** Fokker Model F.28 Mark 0100
- **Type:** Rule
- **Action:** Final rule.
- **Citation:** 70 FR 34642
- **Publication date:** 2005-06-15
- **Effective date:** 2005-07-20
- **FAA docket:** Docket No. FAA-2005-20868
## Abstract

The FAA is adopting a new airworthiness directive (AD) for all Fokker Model F.28 Mark 0100 airplanes. This AD requires an inspection to determine the part number of the passenger service unit (PSU) panels for the PSU modification status, and corrective actions if applicable. This AD is prompted by reported incidents of smoke in the passenger compartment during flight. One of those incidents also included a burning smell and consequently led to emergency evacuation of the airplane. We are issuing this AD to prevent overheating of the PSU panel due to moisture ingress, which could result in smoke or fire in the passenger cabin.

## Source
- [Federal Register document](https://www.federalregister.gov/documents/2005/06/15/05-11694/airworthiness-directives-fokker-model-f28-mark-0100-airplanes)
---
*AI Analytics · CC0 1.0*