← FAA Federal Register actions

Airworthiness Directives; Gulfstream Aerospace Corporation Model GV and GV-SP Airplanes

airworthiness · Rule · Final rule. · Published 2011-11-29 · Effective 2012-01-03 · 76 FR 73483

Document

Document number
2011-29806
Federal Register citation
76 FR 73483
Type
Rule
Action
Final rule.
Category
airworthiness
Manufacturer
Gulfstream Aerospace Corporation Model GV and GV-SP
Publication date
2011-11-29
Effective date
2012-01-03
FAA docket
Docket No. FAA-2011-0572

Abstract

We are adopting a new airworthiness directive (AD) for certain Gulfstream Aerospace Corporation Model GV and GV-SP airplanes. This AD was prompted by notification from the airplane manufacturer that the third fire extinguisher bottle is mounted in a small-fragment impact zone. This AD requires inspecting to determine whether a third Halon fire extinguisher bottle is installed in the auxiliary power unit (APU) fragment impact zone, revising the limitations section of the airplane flight manual to add restrictions for APU usage for certain airplanes having a third fire extinguisher bottle, and removing the third fire extinguisher bottle from certain airplanes. We are issuing this AD to prevent penetration of the bottle by fragments released due to a failure of the APU rotor system. The bottle could rupture and cause substantial damage to primary airframe structure and primary flight controls.

Source

Authoritative
Federal Register document
Machine
JSON-LD · Markdown