airworthiness · Rule · Final rule. · Published 2012-06-25 · Effective 2012-07-30 · 77 FR 37784
Document
Document number
2012-14547
Federal Register citation
77 FR 37784
Type
Rule
Action
Final rule.
Category
airworthiness
Manufacturer
Fokker Services B.V.
Publication date
2012-06-25
Effective date
2012-07-30
FAA docket
Docket No. FAA-2012-0300
Abstract
We are adopting a new airworthiness directive (AD) for all Fokker Services B.V. Model F.28 Mark 0070 and 0100 airplanes. This AD was prompted by a design review which revealed the absence of electrical insulation material between a wing or integral center wing tank (ICWT) fuel quantity indication system (FQIS) probe and the bottom of the tank structure. This AD requires for all airplanes, applying sealant below the FQIS probes in the wing tanks; and for certain airplanes, applying sealant below the FQIS probes in the ICWT. This AD also requires revising the aircraft maintenance program by revising the fuel airworthiness limitations and incorporating critical design configuration control limitations (CDCCLs). We are issuing this AD to prevent an ignition source in the tank vapor space, which could result in a fuel tank explosion and consequent loss of the airplane.