← FAA Federal Register actions

Airworthiness Directives; Fokker Services B.V. Airplanes

airworthiness · Rule · Final rule. · Published 2012-09-24 · Effective 2012-10-29 · 77 FR 58765

Document

Document number
2012-23055
Federal Register citation
77 FR 58765
Type
Rule
Action
Final rule.
Category
airworthiness
Manufacturer
Fokker Services B.V.
Publication date
2012-09-24
Effective date
2012-10-29
FAA docket
Docket No. FAA-2012-0593

Abstract

We are adopting a new airworthiness directive (AD) for certain Fokker Services B.V. Model F.28 Mark 0070 and 0100 airplanes. This AD was prompted by reports of burned contacts in a certain production break plug and its corresponding receptacle. This AD requires modifying galley power supply wiring by disconnecting it from the affected plug/ receptacle and reconnecting the power supply wiring through splices. We are issuing this AD to prevent a high electrical load, which might lead to overheating of the galley power supply wiring and/or the electrical connector and consequent smoke or fire in the galley area, which could result in damage to the airplane and injury to occupants.