← FAA Federal Register actions

Airworthiness Directives; Bombardier, Inc. Airplanes

airworthiness · Rule · Final rule. · Published 2014-02-25 · Effective 2014-04-01 · 79 FR 10331

Document

Document number
2014-02523
Federal Register citation
79 FR 10331
Type
Rule
Action
Final rule.
Category
airworthiness
Publication date
2014-02-25
Effective date
2014-04-01
FAA docket
Docket No. FAA-2013-0705

Abstract

We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc. Model BD-700-1A10 airplanes. This AD was prompted by a report that the manufacturer has determined that some completion centers used the heater/brake monitoring unit (HBMU) logic circuit to control the line voltage of the drain mast heaters. Since the drain mast heaters are connected in parallel with the number 2 pitot static (PS) probe heater circuit, a number 2 PS probe heater failure may not be detected by the fault monitoring capabilities of the HBMU. This AD requires modification of the air data probes and sensors. We are issuing this AD to detect and correct an unannunciated failure of two PS probe heaters, which could affect controllability of the airplane in icing conditions.