Airworthiness Directives; Bombardier, Inc. Airplanes

airworthiness · Rule · Final rule. · Published 2014-08-15 · Effective 2014-09-19 · 79 FR 48030

Document

Document number
2014-18306
Federal Register citation
79 FR 48030
Type
Rule
Action
Final rule.
Category
airworthiness
Publication date
2014-08-15
Effective date
2014-09-19
FAA docket
Docket No. FAA-2013-1068

Abstract

We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc. Model DHC-8-400 series airplanes. This AD was prompted by reports of failure of the high pressure shutoff valves (HPSOVs) causing the timer and monitor unit (TMU) to become inoperative since the HPSOV and the TMU are on the same circuit breaker. This AD requires a wiring modification to segregate the HPSOV power supply from the TMU. We are issuing this AD to prevent an inoperative TMU, which could result in the loss of the automatic de-icing mode, and lead to an increased workload for the flight crew and loss of control of the airplane.