← FAA Federal Register actions

Airworthiness Directives; Pratt & Whitney Division Turbofan Engines

airworthiness · Rule · Final rule. · Published 2020-12-10 · Effective 2021-01-14 · 85 FR 79408

Document

Document number
2020-26915
Federal Register citation
85 FR 79408
Type
Rule
Action
Final rule.
Category
airworthiness
Manufacturer
Pratt & Whitney Division Turbofan
Publication date
2020-12-10
Effective date
2021-01-14
FAA docket
Docket No. FAA-2020-0542

Abstract

The FAA is adopting a new airworthiness directive (AD) for all Pratt & Whitney Division (PW) PW4164, PW4164-1D, PW4168, PW4168-1D, PW4168A, PW4168A-1D, and PW4170 model turbofan engines with a certain outer combustion chamber assembly and 3rd stage low-pressure turbine (LPT) duct segments installed. This AD was prompted by reports of damaged or failed 3rd stage LPT duct segments on PW engines with the Talon IIB outer combustion chamber assembly configuration installed. This AD requires removing and replacing certain 3rd stage LPT duct segments. The FAA is issuing this AD to address the unsafe condition on these products.