# Airworthiness Directives; Airbus Canada Limited Partnership (Type Certificate Previously Held by C Series Aircraft Limited Partnership (CSALP); Bombardier, Inc.) Airplanes
> **Rule** · Final rule. · Published 2022-01-27 · Effective 2022-03-03 · 87 FR 4148
## Document
- **Document number:** 2022-01567
- **Category:** airworthiness
- **Manufacturer:** Airbus Canada Limited Partnership (Type Certificate Previously Held by C Series
- **Type:** Rule
- **Action:** Final rule.
- **Citation:** 87 FR 4148
- **Publication date:** 2022-01-27
- **Effective date:** 2022-03-03
- **FAA docket:** Docket No. FAA-2021-0615
## Abstract

The FAA is adopting a new airworthiness directive (AD) for certain Airbus Canada Limited Partnership Model BD-500-1A10 and BD-500- 1A11 airplanes. This AD was prompted by a report indicating that during production, the manual opening and closing of the over-wing emergency exit door (OWEED) prior to the installation of the OWEED interior panel could have resulted in damaged insulation blankets below the left and right OWEEDs. This AD requires a one-time inspection for damage of the insulation blankets below the left and right OWEEDs, and replacement if necessary, as specified in a Transport Canada Civil Aviation (TCCA) AD, which is incorporated by reference. The FAA is issuing this AD to address the unsafe condition on these products.

## Source
- [Federal Register document](https://www.federalregister.gov/documents/2022/01/27/2022-01567/airworthiness-directives-airbus-canada-limited-partnership-type-certificate-previously-held-by-c)
---