← FAA Federal Register actions

Airworthiness Directives; McDonnell Douglas Model DC-10-10, DC-10-10F, DC-10-30, DC-10-30F (KDC-10), DC-10-40, and DC-10-40F Airplanes

airworthiness · Rule · Final rule. · Published 2006-08-09 · Effective 2006-09-13 · 71 FR 45368

Document

Document number
E6-12827
Federal Register citation
71 FR 45368
Type
Rule
Action
Final rule.
Category
airworthiness
Publication date
2006-08-09
Effective date
2006-09-13
FAA docket
Docket No. FAA-2006-24864

Abstract

The FAA is adopting a new airworthiness directive (AD) for certain McDonnell Douglas airplanes, identified above. This AD requires reducing the length of the sump drain collar and replacing the fuel tank sump drain lockring for fuel tanks 1, 2, and 3; and reducing the length of the drain outlet barrel for the auxiliary fuel tank, if applicable. For airplanes with an auxiliary fuel tank, this AD also requires relocating the sump drain outlet to allow draining the sumps without opening the doors of the main landing gear wheel well. This AD results from fuel system reviews conducted by the manufacturer. We are issuing this AD to reduce the potential of ignition sources inside fuel tanks in the event of a lightning strike, which, in combination with flammable fuel vapors, could result in arcing in the fuel tank, fuel tank explosions, and consequent loss of the airplane.

Source

Authoritative
Federal Register document
Machine
JSON-LD · Markdown