Federal Data HubEPA RMP · JSON

Chevron-Phillips Chemical Company LP, Sweeny

Parent: Chevron Phillips Chemical Company LP · EPA RMP facility · Sweeny, TX

Chevron-Phillips Chemical Company LP, Sweeny is regulated under the Clean Air Act Risk Management Program (§112(r)) because it stores or uses hazardous chemicals above threshold quantities. It has 3 reportable chemical accident(s) on record. RMP accidents include toxic/flammable releases, fires, explosions, and reactive incidents.

Accident history

DateTypeDeathsInjuriesEvacuatedCause
2021-02-15Fire, Explosion000Improper procedure, Overpressurization
2017-08-27Fire000Equipment failure, Process design failure
2015-11-07Gas release, Fire000Equipment failure, Process design failure

About this data

The EPA Risk Management Program (Clean Air Act §112(r)) requires facilities with large quantities of hazardous chemicals to file Risk Management Plans, including a 5-year accident history. EPA keeps this statutorily-public data available only via FOIA / reading rooms; this page mirrors the FOIA'd dataset (institution-level only — no personal contact information).

Source: EPA RMP (FOIA mirror via the Data Liberation Project). License: CC0 1.0.