Federal Data HubEPA RMP · JSON

Dow Corning Corporation Carrollton Site

Parent: The Dow Chemical Company · EPA RMP facility · Carrollton, KY

Dow Corning Corporation Carrollton Site is regulated under the Clean Air Act Risk Management Program (§112(r)) because it stores or uses hazardous chemicals above threshold quantities. It has 9 reportable chemical accident(s) on record, causing 0 death(s) and 17 injuries. RMP accidents include toxic/flammable releases, fires, explosions, and reactive incidents.

Accident history

DateTypeDeathsInjuriesEvacuatedCause
2010-08-29Gas release, Fire010Maintenance
2004-11-18Spill000Equipment failure, Human error
2004-07-22Gas release, Spill010Equipment failure, Process design failure
2003-11-07Spill010Human error, Improper procedure
2003-10-30Gas release, Spill030Human error, Improper procedure
2003-06-29Gas release010Human error, Improper procedure
2002-12-13Gas release, Spill010Equipment failure, Human error
2002-05-18Gas release020Human error, Improper procedure
2002-05-17Gas release070Human error, Improper procedure

About this data

The EPA Risk Management Program (Clean Air Act §112(r)) requires facilities with large quantities of hazardous chemicals to file Risk Management Plans, including a 5-year accident history. EPA keeps this statutorily-public data available only via FOIA / reading rooms; this page mirrors the FOIA'd dataset (institution-level only — no personal contact information).

Source: EPA RMP (FOIA mirror via the Data Liberation Project). License: CC0 1.0.