The Nuclear Regulatory Commission (NRC) is amending its regulations revising the BNG Fuel Solutions Corporation VSC-24 cask system listing within the "List of Approved Spent Fuel Storage Casks" to include Amendment No. 6 to Certificate of Compliance Number 1007. Amendment No. 6 will modify the present cask system design to revise the Technical Specification (TS) requirements related to periodic monitoring during storage operation under a general license. Specifically, the amendment will eliminate TS 1.3.4 that requires daily temperature measurement of the cask. The daily temperature measurement is not required because the daily visual inspection of the cask inlet and outlet vent screens, required by TS 1.3.1, provides the capability to determine when corrective action needs to be taken to maintain safe storage conditions under the requirements that govern general design criteria for spent fuel storage casks. This is because the visual inspection would determine if the cask inlets and outlets were blocked (the focus of the thermal analysis submitted by the CoC holder). The amendment will also revise TS 1.2.3 to correspond with TS 1.3.1 by revising the method of thermal performance evaluation to allow for daily temperature surveillance after the cask has reached thermal equilibrium. In addition, the amendment updates editorial changes associated with the company name change from BNFL Fuel Solutions Corporation to BNG Fuel Solutions Corporation.