← Energy + Nuclear Federal Register rules

Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnaces and Boilers

other · US Department of Energy · Published 2016-01-15 · Effective 2016-02-16 · 81 FR 2628

Document

Document number
2016-00040
Federal Register citation
81 FR 2628
CFR reference
10 CFR 429
Type
Rule
Action
Final rule.
Category
other
Sub-agency
US Department of Energy
Publication date
2016-01-15
Effective date
2016-02-16
Energy docket
Docket No. EERE-2012-BT-TP-0024

Abstract

The U.S. Department of Energy (DOE) amends its test procedure for residential furnaces and boilers established under the Energy Policy and Conservation Act. This rulemaking will fulfill DOE's obligation to review its test procedures for covered products at least once every seven years. The revisions include: Clarifying the components included in the burner electrical power input term (PE); adopting a method for determining whether a minimum draft factor can be applied, and how the conditions are to be verified; allowing optional measurement of condensate collection during establishment of steady state; updating references to the applicable installation and operating manual and providing clarifications when the installation and operation (I&O) manual does not specify test setup; clarifying the testing of units intended to be installed without a return duct; adopting a provision clarifying the testing of multi-position units; revising the required reporting precision for annual fuel utilization efficiency (AFUE); and adopting a verification method for determining whether a boiler incorporates an automatic means for adjusting water temperature and whether this design requirement functions as required.

Source

Authoritative
Federal Register document
Machine