← Energy + Nuclear Federal Register rules

Energy Conservation Program: Test Procedure for Commercial Warm Air Furnaces

energy-efficiency · US Department of Energy · Published 2023-06-02 · Effective 2023-07-03 · 88 FR 36217

Document

Document number
2023-11341
Federal Register citation
88 FR 36217
CFR reference
10 CFR 431
Type
Rule
Action
Final rule.
Category
energy-efficiency
Sub-agency
US Department of Energy
Publication date
2023-06-02
Effective date
2023-07-03
Energy docket
EERE-2019-BT-TP-0041

Abstract

The U.S. Department of Energy (DOE) is amending the Federal test procedures for commercial warm air furnaces (CWAFs) to incorporate the latest versions of the industry test standards that are currently incorporated by reference. DOE is also establishing a new metric, Thermal Efficiency Two (TE2), and corresponding test procedure. Use of the newly established test procedure would become mandatory at such time as compliance with amended energy conservation standards based on TE2 is required, should DOE adopt such standards. DOE also is adopting additional specifications for CWAFs with multiple flue outlets or small flue outlets.

Source

Authoritative
Federal Register document
Machine