# ROLL COATER, INC.
> **Administrative - Formal** · FY2010 · — · Final Order With Penalty
## Case
- **Activity ID:** `2200004197`
- **Case Number:** 04-2010-4005
- **Type:** Administrative - Formal
- **Lead:** EPA
- **Outcome:** Final Order With Penalty
- **Penalty assessed:** —
- **Cost recovery:** —
- **Compliance action $:** —
- **Multimedia (multi-env):** —
## Defendants
- ROLL COATER, INC. (complaint) (settlement)
## Summary

8/31/10 - CONSENT AGMT AND FINAL ORDER ISSUED, ASSESSING A PENALTY OF $51,000. 

ON DEC 2, 2008, EPA AND KYDEP CONDUCTED A JOINT RCRA COMPLIANCE EVALUATION INSPECTION (CEI) AT THE FACILITY.

AT THE TIME OF THE CEI:
EPA AND KYDEP REPS OBSERVED THAT RESPONDENT DID NOT HAVE AN AIR EMISSION MONITORING PROGRAM FOR THE HAZ WASTE TANK SYSTEM, AS REQUIRED IN 40 CFR PART 265, SUBPART BB. SPECIFICALLY, RESPONDENT FAILED TO:
A. MARK EACH PIECE OF EQUIPMENT TO WHICH SUBPART BB APPLIES IN SUCH A MANNER THAT IT CAN BE DISTINGUISHED READILY FROM OTHER PIECES OF EQUIPMENT; 
B. KEEP A FACILITY OPERATING RECORD THAT INCLUDES: (i) EQUIPMENT ID # AND HAZ WASTE MGMT UNIT ID; (ii) APPROX LOCATIONS WITHIN FACILITY; (iii) PERCENT-BY-WEIGHT TOTAL ORGANICS; (v) HAZ WASTE STATE AT THE EQUIPMENT; AND (vi) METHOD OF COMPLIANCE WITH THE STANDARD;
C. PERFORM MONTHLY LEAK DETECTION MONITORING AND WEEKLY VISUAL INSPECTION OF THE PUMPS; AND
D. PERFORM MONTHLY LEAK DETECTION MONITORING OF VALVES.

PURSUANT TO RESPONDENT'S AIR QUALITY TITLE V PERMIT ISSUED BY KY DIV FOR AIR QUALITY (KDAQ) ON JAN 29, 2008, FACILITY WAS COLLECTING AND DESTROYING A PORTION OF THE VOC EMISSIONS FROM THE PRIME COATING AREAS #1 AND #2 AND THE 5,000 GAL SPENT SOLVENT ACCUMULATION TANK IN THE PAINT STORAGE BLDG WHEN COATING WAS OCCURRING. THIS PROCESS INVOLVING CAPTURING VAPORS FROM FACILITY'S PERMANENT TOTAL ENCLOSURE SYSTEM AND DIRECTING IT TO A THERMAL OXIDIZER. RESOPNDENT USES THE THERMAL OXIDIZER TO ENABLE FACILITY TO M

---