← EPA enforcement cases

BABCOCK AND WILCOX POWER GENERATION GROUP, INC

Administrative - Formal · FY2012 · — · Default Order With Penalty · 3000024989

Penalty
Cost recovery
Compliance action

Case

Case Number
05-2012-5025
Type
Administrative - Formal
Lead
EPA
Outcome
Default Order With Penalty
Multimedia
Self-disclosure
N

Defendants (1)

Summary

EPA inspected B&W, a foundry, on May 25, 2011. During the night-portion of the inspection, EPA observed visible emissions emanating from the broken duct leading to the baghouse serving an electric arc furnace (EAF), as well as visible emissions leaving the stack (vent) exiting the baghouse serving the EAF. On August 30, 2011, EPA issued an NOV to B&W. The NOV alleged B&W failed to maintain the capture and control system associated with its EAF. B&W returned to compliance on June 8, 2011, when it completed maintenance on the fan and associated baghouse. B&W has also agreed to pay a penalty of $43,566.