1. SECTION 113 OF THE CLEAN AIR ACT ( CAA ), 42 U.S.C. SEC- TION 7413. 2. CYTEC INDUSTRIES, INC. 10800 RIVER ROAD WAGGAMAN, JEFFERSON PARISH, LOUISIANA 70094 3. AN AIR INSPECTION WAS CONDUCTED AT THE CYTEC INDUSTRIES, INC. FORTIER PLANT, WAGGAMAN, JEFFERSON PARISH, LOUISIANA FACILITY, ON JUL. 23 THROUGH JUL. 25,, 1996. THE LA. DEPT OF ENV. QUALITY (LDEQ) WAS ASKED TO PARTICIPATE IN THE INSPECTION BUT DECLINED. THE RESULTS OF THE INSPECTION WERE SENT TO THE LDEQ BY THE EPA INSPECTOR. FOLLOWING THE INSPECTION AND REVIEW OF RECORDS PROVIDED BY CYTEC, EPA FOUND VIOLATIONS OF THE NATIONAL EMISSION STANDARDS FOR ORGANIC HAZARDOUS AIR POLLUTANTS, ALSO KNOWN AS HAZARDOUS ORGANIC NESHAPS (HON) AND STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES OR NEW SOURCE PERFORMANCE STAND- ARDS (NSPS). THE VIOLATIONS WERE 1) FAILING TO EQUIP EACH OPEN-ENDED VALVE OR LINE WITH A CAP, BLIND FLANGE, PLUG, OR A SECONDVALVE, 2) FAILING TO PROVIDE ALL OF THE IN- FORMATION REQUIRED IN THE NOTIFICATION OF COMPLIANCE STA- TUS REPORT FOR THE ACRYLAMIDE UNIT, ACRYLONITRILE UNIT, ACRYLONITRILE UNIT, ACRYLONITRILE TANK FARM, METHANOL UNIT, METHANOL TANK FARM, AND METHYL METHACRYLATE UNIT, 3) FAILING TO REPAIR A DETECTED LEAK FROM PUMP T-5 IN THE METHYL METHACRYLATE UNIT NO LATER