# BAYER CORPORATION
> **Administrative - Formal** · FY1997 · — · Final Order With Penalty
## Case
- **Activity ID:** `37277`
- **Case Number:** 06-1997-0447
- **Type:** Administrative - Formal
- **Lead:** EPA
- **Outcome:** Final Order With Penalty
- **Penalty assessed:** $55K
- **Cost recovery:** —
- **Compliance action $:** $14K
- **Multimedia (multi-env):** N
## Defendants
- BAYER CORPORATION (complaint) (settlement)
## Summary

1. SECTION 113(D) OF THE CLEAN AIR ACT ( CAA ), AS AMENDED,     42 U.S.C. SECTION 7413(D).                                2. BAYER CORPORATION                                            1006 FARM ROAD                                               ORANGE, ORANGE COUNTY, TEXAS 77631-2000                   3. RESPONDENT WAS IN VIOLATION OF SECTION 112 OF THE CAA        FAILING TO COMPLY WITH THE STANDARDS FOR OPENED ENDED        VALVES OR LINES, AND BY FAILING TO TEST THE CONTROL DE-      VICE.                                                     4. RELIEF SOUGHT PURSUANT TO SECTION 113(D) OF THE CAA, EPA     PROPOSES A PENALTY OF $55,000.

---