← EPA enforcement cases

W H CHRISTIAN & SONS INC.

Administrative - Formal · FY2001 · — · — · 8300

Penalty
Cost recovery
Compliance action

Case

Case Number
02-2001-1265
Type
Administrative - Formal
Lead
EPA
Outcome
Multimedia
N
Self-disclosure
N

Defendants (1)

Summary

RESPONDENT FAILED TO INSPECT THE COMPONENTS OF THE DRY CLEANING SYSTEM ON AT LEAST ON A BIWEEKLY BASIS FOR PERCEPTIBLE LEAKS WHILE THE DRY CLEANING SYSTEM IS OPERATING; FAILED TO MEASURE THE TEMPERATURE OF THE AIR-PER GAS- VAPOR STREAM ON THE OUTLET SIDE OF THE REFRIGERATED CONDENSOR ON A DRY-TO-DRY MACHINE WITH A TEMPERATURE SENSOR ON A WEEKLY BASIS; FAILED TO CALCULATE THE DIFFERENCE BETWEEN THE TEMPERATURE OF THE AIR-PER GAS-VAPOR STREAM ENTERING & EXITING THE REFRIGERATED CONDENSOR ON A WASHER WEEKLY TO DETERMINE THAT THE DIFFERENCE IS GREATER THAN OR EQUAL TO 20OF; FAILED TO KEEP A LOG OF THE DATES WHEN DRY CLEANING SYSTEM COMPONENTS ARE INSPECTED FOR PERCEPTIBLE LEAKS & THE NAME & LOCATION OF DRY CLEANING SYSTEM COMPONENTS WHERE PERCEPTIBLE LEAKS ARE DETECTED; AND FAILED TO KEEP NECESSARY RECORDS REGARDING THE TEMPERATURE SENSOR MONITORING RESULTS RELEVANT TO THE PROPER OPERATION OF THE REFRIGERATED CONDENSOR & THE DATE(S) ON WHICH THE TEMPERATURE MONITORING WAS PERFORMED.

Source

Authoritative
EPA ECHO
Machine
JSON-LD · Markdown