# FOUR SEASONS CLEANERS
> **Administrative - Formal** · FY2001 · — · Final Order With Penalty
## Case
- **Activity ID:** `8302`
- **Case Number:** 02-2001-1267
- **Type:** Administrative - Formal
- **Lead:** EPA
- **Outcome:** Final Order With Penalty
- **Penalty assessed:** —
- **Cost recovery:** —
- **Compliance action $:** —
- **Multimedia (multi-env):** N
## Defendants
- FOUR SEASONS CLEANERS (complaint) (settlement)
## Summary

FOUR SEASONS FAILED TO PERFORM BIWEEKLY INSPECTION AND TO    KEEP A LOG OF DATES WHEN DRY CLEANING SYSTEMS COMPONENTS     WERE INSPECTED FOR PERCEPTIBLE LEAKS WHILE THE DRY CLEANING  SYSTEM WAS IN OPERATION; FAILED TO MONITOR THE TEMPERATURE   OF THE AIR-PERC GAS-VAPOR STREAM ON THE OUTLET SIDE OF THE   REFRIGERATED CONDENSER ON A DRY-TO-DRY MACHINE AND TO        MAINTAIN A 45 F OR LESS, THE TEMPERATURE OF THE AIR-PERC AND FAILED TO ADJUST/REPAIR THE DRY CLEANING SYSTEM OR CONTROL   DEVICE TO MEET THE VALUES SPECIFIED IN SECTION 63.323(A), AS REQUIRED.                                                    *                                                 ccds case summary has a few words changed from the case initiation form.  See the hard copy form in the file or the CCDS in the notes database forms system.

---