# FRANCISE CLEANERS INC
> **Administrative - Formal** · FY2002 · — · Final Order With Penalty
## Case
- **Activity ID:** `8764`
- **Case Number:** 02-2002-1287
- **Type:** Administrative - Formal
- **Lead:** EPA
- **Outcome:** Final Order With Penalty
- **Penalty assessed:** —
- **Cost recovery:** —
- **Compliance action $:** —
- **Multimedia (multi-env):** N
## Defendants
- FRANCISC CLEANERS INC (complaint) (settlement)
## Summary

FRANCISE CLEANERS INC. FAILED TO INSPECT THE COMPONENTS OF   THE DRY CLEANING SYSTEM FOR PERCEPTIBLE LEAKS WHILE THE      CLEANING SYSTEM IS OPERATING AND TO MEASURE THE TEMPERATURE  OF THE AIR-PER GAS-VAPOR STREAM ON THE OUTLET SIDE OF THE    REFRIGERATED CONDENSER ON A DRY-TO-DRY MACHINE WITH A        TEMPERATURE SENSOR ON A BIWEEKLY BASIS; FAILED TO KEEP A LOG OF THE VOLUME OF PERC USED BY THE FACILITY; FAILED TO KEEP A LOG OF DATES WHEN DRY CLEANING SYSTEM COMPONENTS ARE INSPEC- TED FOR PERCEPTIBLE LEAKS, AND THE NAME AND LOCATION OF DRY  CLEANING SYSTEM COMPONENTS WHERE PERCEPTIBLE LEAKS ARE DE-   TECTED; AND FAILED TO KEEP NECESSARY RECORDS REGARDING THE   TEMPERATURE SENSOR MONITORING RESULTS RELEVANT TO THE PROPER OPERATION OF THE REFRIGERATED CONDERSER AND THE DATE(S) ON   WHICH THE TEMPERATURE MONITORING WAS PERFORMED.              *   
The respondents' name was given as FRANCISE when the CA/CO was issued.  The respondent notified ORC the correct spelling of their name is: FRANCISC.

---
*Source: [EPA ECHO](https://echo.epa.gov/) · AI Analytics · CC0 1.0*