# Hazardous Waste Management System; Identification and Listing of Hazardous Waste; Final Exclusion
> **Rule** · Final rule. · Published 2011-11-23 · Effective 2011-11-23 · 76 FR 72311
## Document
- **Document number:** 2011-30147
- **Category:** hazardous-waste
- **Federal Register citation:** 76 FR 72311
- **CFR reference:** 40 CFR 261
- **Publication date:** 2011-11-23
- **Effective date:** 2011-11-23
- **EPA docket:** EPA-R06-RCRA-2009-0312
## Abstract

The Environmental Protection Agency (EPA) is granting a petition submitted by Eastman Chemical Corporation--Texas Operations (Eastman Chemical) to exclude from hazardous waste control (or delist) a certain solid waste. This final rule responds to the petition submitted by Eastman Chemical to delist three waste streams generated from its rotary kiln incinerator (RKI). These waste streams are the rotary kiln incinerator (RKI) bottom ash, RKI fly ash, and RKI scrubber water blowdown. The RKI bottom ash and the RKI fly ash are derived from the management of several F-, K-, and U-waste codes. These waste codes are F001, F002, F003, F005, F039, K009, K010, U001, U002, U031, U069, U107, U112, U117, U140, U147, U161, U213, and U359. The Scrubber water blowdown produced by the RKI's air pollution control equipment is also derived from the management of several F-, K-, and U-waste codes as well as certain characteristic hazardous wastes. These waste codes are D001, D002, D003, D007, D008, D018, D022, F001, F002, F003, F005, F039, K009, K010, U001, U002, U031, U069, U107, U112, U117, U140, U147, U161, U213, and U359. The RKI is authorized to manage a list of additional F- , K-, U-, and P- codes to cover off-site sources not attributed to the above waste codes. If these waste codes are not specifically listed in the delisting exclusion, they are not covered by the exclusion and can not be managed as non-hazardous, unless and until, the exclusion is modified to include them. After careful analysis and evaluation of comments submitted by the public, the EPA has concluded that the petitioned wastes are not hazardous waste when disposed of in Subtitle D landfills or in the case of the scrubber water blowdown, discharged in conjunction with its TPDES discharge permit. This exclusion applies to the RKI bottom ash, RKI fly ash and RKI scrubber water blowdown generated at Eastman Chemical's Longview, Texas facility. Accordingly, this final rule excludes the petitioned waste from the re

## Source
- [Federal Register document](https://www.federalregister.gov/documents/2011/11/23/2011-30147/hazardous-waste-management-system-identification-and-listing-of-hazardous-waste-final-exclusion)
---
*AI Analytics · CC0 1.0*