VIRTUAL PELVIC SURGERY SIMULATOR FOR THE PREVENTION OF SURGICAL ERRORS

NIH RePORTER · NIH · R21 · $228,455 · view on reporter.nih.gov ↗

Abstract

Project Summary Surgical errors are commonplace and can have devastating consequences. More than 200 million surgeries occur annually worldwide and, in industrialized countries, preventable complications occur in up to 22% of cases for some procedures. Consequent permanent disability or mortality rates range between 0.4% and 0.8%. Errors can have numerous origins, including cognitive errors of judgment, missing a surgical step, performing them in the wrong order, or simply committing an error in technical execution. These can lead to poor surgical outcomes, poor patient satisfaction, reoperation, and litigation. Most surgeons are well aware of the high-risk steps in a given procedure, yet for most there is no widespread and reliable technology to prevent errors. We propose groundbreaking research in surgical error prevention by developing simulation technology, based on mathematical reconstructions of human tissue that can be utilized for our overall mission, to create a system to identify, model, and prevent surgical errors. To accomplish this, we will use motion analysis and high-fidelity 3-D models to simulate and measure surgical errors. We will analyze errors in a complex, high-risk step of one particular surgery, the midurethral sling (MUS) procedure. This surgery is an ideal choice for modeling individual surgeon error. Approximately 170,000 MUS surgeries are performed annually in the United States, a number that will likely increase given the aging US population. In performing the MUS, the surgeon is tasked with blindly guiding a sharp steel trocar past the bladder, bowel, and major blood vessels, so the surgeon must exhibit excellent bimanual dexterity and the ability to envision a blind 3-D space. If the trocar is not guided properly, complications can turn an elective minor surgery into a costly, protracted hospital course that may involve blood transfusions, a bowel resection, a colostomy, even sepsis and death. Novices are understandably anxious about performing this on a patient. We hypothesize that surgical error from trocar passage in the MUS surgery can be predicted, and thus avoided, by discrete changes in the kinematics of the surgeon’s shoulder, arm, and hand and by the spatio-temporal characteristics of trocar passage. We will create a 3-D pelvic simulator and use motion analysis with sensors to identify and prevent surgical errors during this complex, high-risk step. We will test the hypothesis with the following Aims: Aim 1: Create a high-fidelity pelvic simulator capable of identifying surgical errors involved in one surgery, the midurethral sling. Aim 2: Identify the kinematics of surgeon gross motor movements and of the surgical instrument during simulated trocar passage. Aim 3: Develop virtual surgical feedback software that when added to a printed pelvic simulation model will further reduce novice errors in the Midurethral Sling surgery. Our high-impact research and multi- disciplinary team is revolutionary in its appr...

Key facts

NIH application ID
10004033
Project number
5R21EB025272-03
Recipient
UNIVERSITY OF MISSOURI KANSAS CITY
Principal Investigator
Gary Sutkin
Activity code
R21
Funding institute
NIH
Fiscal year
2020
Award amount
$228,455
Award type
5
Project period
2018-09-14 → 2022-06-30