PROJECT SUMMARY / ABSTRACT
 2 Nonlinear algorithms such as model-based reconstruction (MBR) and deep learning (DL) reconstruction have
 3 sparked tremendous research interest in recent years. Compared to traditional linear approaches, the nonline-
 4 arity of these algorithm transcends traditional signal-to-noise requirement and offer flexibility to draw information
 5 from a variety of sources (e.g., statistical model, prior image, dictionary, training data). MBR has enabled numer-
 6 ous advancements including low-dose CT and advanced scanning protocols. Deep learning algorithms are rap-
 7 idly emerging and have demonstrated superior dose vs. image quality tradeoffs in research settings. However,
 8 widespread clinical adoption of nonlinear algorithms has been impeded by the lack of a lack of systematic, quan-
 9 titative methods for performance analysis. Nonlinear methods come with numerous dependencies on the imag-
10 ing techniques, the imaging target, and the prior information, and the data itself. The relationship between these
11 dependencies and image quality is often opaque. Furthermore, improper selection of algorithmic parameters can
12 lead to erroneous features (e.g., smaller lesions, texture) in the reconstruction. Therefore, methods to quantify
13 and predict performance permit efficient and quantifiable performance evaluation to provide the robust control
14 and understanding of imaging output necessary for reliable clinical application and regulatory oversight.
15 We propose to establish a robust, predictive framework for performance assessment and optimization that can
16 be generalized to any reconstruction method. We quantify performance in turns of the perturbation response and
17 covariance as a function of imaging techniques, system configurations, patient anatomy, and, importantly, the
18 perturbation itself. The perturbation response quantifies the appearance (e.g., biases, blurs, distortions), and,
19 together with the covariance, allows the computation of more complex metrics such as task-based performance
20 and radiomic measures including size, shape, and texture information. We illustrate utility of the approach in lung
21 imaging with the following specific aims: Aim 1: Develop a lesion library and generate perturbations encom-
22 passing clinically relevant features. We will extract lesions from public databases and develop methods lesion
23 emulation in for realistic CT simulation and physical data via 3D printing technology. Aim 2: Develop a gener-
24 alized prediction framework for perturbation response and covariance. Using analytical and neural network
25 modeling, we will establish a framework that predicts perturbation response and covariance across imaging
26 scenarios for classes of algorithms with increasing data-dependence including MBR with a Huber penalty, MBR
27 with dictionary regularization, and a deep learning reconstructor. Aim 3: Develop assessment and optimiza-
28 tion strategies to drive ro...

## Key facts

- **NIH application ID:** 10121056
- **Project number:** 1R01CA249538-01A1
- **Recipient organization:** JOHNS HOPKINS UNIVERSITY
- **Principal Investigator:** Jianan Grace Gang
- **Activity code:** R01 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 2021
- **Award amount:** $512,567
- **Award type:** 1
- **Project period:** 2021-01-01 → 2024-12-31

## Primary source