# Portable MRI Technology for Neonatal Care

> **NIH NIH R01** · MASSACHUSETTS GENERAL HOSPITAL · 2021 · $510,303

## Abstract

Project Summary/Abstract
 Magnetic Resonance Imaging (MRI), especially with diffusion contrast, has been the undisputed standard
of care for the detection and diagnosis of neonatal brain disorders and injuries such as Hypoxic-ischemic
encephalopathy (HIE). However, the nature of these large, expensive, potentially dangerous instruments limits
accessibility and requires that patients be transported to a radiology suite. In the neonatal intensive care unit
(NICU) setting, patient transfer introduces safety concerns, since it requires a full hand-off of patient care
responsibilities and exposes the neonate to stress from transport and acoustic noise. In particular, HIE patients
are often not stable enough to transfer to the scanner for several days after birth. Instead bed-side cranial
imaging is performed with ultrasound, which has a low sensitivity for early abnormalities associated with HIE.
 We design a bed-side scanner specifically for the needs of neonatal brain imaging in an NICU. The
proposed scanner will be transported to the bedside in the NICU, prioritizing minimal handling and
manipulation of the infant and enabling true POC diagnostics and monitoring. We significantly reduce the size,
cost, and complexity of conventional MRI hardware by designing for the smaller FOV needed for neonatal
brain imaging and significantly depart from the canonical scanner design. The magnet, field gradients, and RF
coils will be optimized for the smaller imaging volume to maximize image quality. To allow operation outside an
RF shielded room, we propose an EMI mitigation method that retrospectively removes artifacts using external
detectors. As DWI imaging is highly valuable in the HIE patient population, we will develop a RARE DWI
sequence for the unconventional scanner architecture. The new scanner will first be validated with an
anthropomorphic neonatal phantom with realistic tissue properties and then at the MGH Neonatal ICU as an
addition to the standard care of HIE patients. We will determine if the POC MRI offers valuable early
information about the brain condition, which is corroborated in later high-field MRI images obtained when the
baby is stable enough to be transferred to the conventional scanner.

## Key facts

- **NIH application ID:** 10179580
- **Project number:** 1R01HD104649-01
- **Recipient organization:** MASSACHUSETTS GENERAL HOSPITAL
- **Principal Investigator:** Clarissa Zimmerman Cooley
- **Activity code:** R01 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 2021
- **Award amount:** $510,303
- **Award type:** 1
- **Project period:** 2021-05-01 → 2026-04-30

## Primary source

NIH RePORTER: https://reporter.nih.gov/project-details/10179580

## Citation

> US National Institutes of Health, RePORTER application 10179580, Portable MRI Technology for Neonatal Care (1R01HD104649-01). Retrieved via AI Analytics 2026-05-23 from https://api.ai-analytics.org/grant/nih/10179580. Licensed CC0.

---

*[NIH grants dataset](/datasets/nih-grants) · CC0 1.0*