Spinal root stimulation for restoration of function in lower-limb amputees

NIH RePORTER · NIH · UH3 · $1,059,120 · view on reporter.nih.gov ↗

Abstract

PROJECT SUMMARY / ABSTRACT Recent advances in design and actuation have led to important improvements in prosthetic limbs. However, these devices lack a means for providing direct sensory feedback, requiring users to infer information about limb state from pressure on the residual limb. Lack of sensation limits their ability to control the prosthesis and leads to slow gait and increased risk of falling. There is also evidence that lack of sensory feedback contributes to phantom limb pain (PLP), and that electrical stimulation at the dorsal root ganglia (DRG) can reduce PLP. The primary objective of this study is to use commercially available, FDA-cleared spinal cord stimulator (SCS) leads to test the effects of electrical stimulation of the DRG and dorsal rootlets (DR) as a means of restoring naturalistic sensation (e.g. pressure, movement), reducing PLP, and improving gait function in transtibial amputees. We will use stimulation to (1) produce sensations of pressure and joint movement, (2) reduce PLP, (3) evoke patterns of muscle activity that mimic automatic responses that occur normally during standing and walking, and (4) improve postural stability when standing and walking with a sensorized prosthesis. Aim 1: Use stimulation of the DRG/DR to generate naturalistic sensations of pressure and joint movement, localized to the amputated limb, and achieve a clinically relevant reduction in phantom limb pain To provide intuitive feedback, evoked sensations should be perceived as originating in the amputated limb and should feel naturalistic. A concomitant reduction in PLP may also have important effects on quality of life. We will perform detailed psychophysical testing in which stimulation parameters are varied while study participants are asked to report information about the evoked sensation (e.g. location, modality, naturalness) and the effects on PLP. Aim 2: Characterize the motor responses in the intact and amputated limbs evoked by DRG/DR stimulation and their relationship to stimulation parameters Bilaterally coordinated reflexes play an important role when responding to unexpected perturbations like slips and trips. Additionally, the transitions between phases of gait are largely mediated by reflexive responses to sensory input from the legs. For a prosthesis to restore the full capabilities of the amputated limb during standing and walking, the ability to evoke and precisely control these patterns of reflexive activity will be critical. We will record electromyogram (EMG) signals from the limbs during standing and walking while varying stimulus patterns and quantify the relationships between stimulation parameters and evoked reflexive responses. Understanding these relationships will aide in the programming of stimulation patterns for functional prosthesis use. Aim 3: Decrease postural sway and increase gait stability by providing sensory feedback via DRG/DR stimulation To quantify the functional impact of sensory restoration on prosthet...

Key facts

NIH application ID
10357668
Project number
5UH3NS100541-04
Recipient
UNIVERSITY OF PITTSBURGH AT PITTSBURGH
Principal Investigator
LEE E FISHER
Activity code
UH3
Funding institute
NIH
Fiscal year
2022
Award amount
$1,059,120
Award type
5
Project period
2017-09-25 → 2024-04-30