Multi-Center Clinical Trial of Spinal Cord Stimulation to Restore Cough

NIH RePORTER · NIH · UG3 · $1,608,519 · view on reporter.nih.gov ↗

Abstract

Respiratory complications account for significant morbidity and mortality in persons with cervical and high thoracic spinal cord injury (SCI) due to their inability to cough. As a consequence, most individuals suffer from a markedly reduced ability to clear airway secretions resulting in the development of recurrent respiratory tract infections.1-16, 128-130,132,135,136 Moreover, diseases of the respiratory system are the leading cause of death in this patient population.3,7,9,12,15 These individuals lack an effective cough mechanism due to paralysis of the muscles of expiration.18-20,42,126-130,132,135,136 We have performed a pilot clinical trial (n=17) with disc electrodes and demonstrated that an effective cough can be restored in SCI.27-29 This method results in near maximal expiratory muscle activation, as reflected by the generation of large airway pressures and peak expiratory airflow rates, which are in the same range as those observed during maximum cough efforts in normal persons.27,28 Use of the system significantly reduces the difficulty in raising secretions and reduces the incidence of respiratory tract infections29,117 Unfortunately, disc electrode placement requires an invasive surgical procedure. In a recent clinical trial of bipolar SCS with parallel wire electrodes (T9–T11 spinal levels), we demonstrated that comparable levels of expiratory muscle activation and clinical benefits can be achieved, when compared to the disc electrodes (n=12).119,120,121a,153 Our current stimulation system entails use of wire electrodes manufactured by Ardiem (Indiana, PA) and electrical stimulator by Finetech, Inc (London, England) (FM). FM however does not have Bluetooth capability, has a cumbersome antenna and does not have a license to allow US commercialization. Therefore, we plan to partner with Avery Biomedical Devices (Commack, NY) (ABD) to construct more advanced and more user-friendly stimulator. The ABD device will have Bluetooth capability allowing for remote activation and facilitate data logging including the ability to view, download and analyze data in real time and the antenna is very flexible with no orientation requirement. In addition, ABD already services patients with respiratory care needs. This stimulator will be used in conjunction with Ardiem wire electrodes, utilized in our recent clinical trial. This device will represent the only commercially available spinal cord stimulator with the range of stimulus parameters required to activate the expiratory muscles and restore an effective cough. The Major Objectives of the proposed study, therefore, are to 1) construct an electrical stimulator to activate the expiratory muscles and connect with the Ardiem electrodes 2) perform the necessary testing required by the FDA to amend our current IDE 3) perform a multi-center clinical trial to determine the utility of SCS with wire leads to produce an effective cough and provide an effective means of clearing airway secretions, reduce ...

Key facts

NIH application ID
10358346
Project number
1UG3NS121560-01A1
Recipient
CASE WESTERN RESERVE UNIVERSITY
Principal Investigator
Anthony F. DiMarco
Activity code
UG3
Funding institute
NIH
Fiscal year
2022
Award amount
$1,608,519
Award type
1
Project period
2022-09-22 → 2025-08-31