National Immunohistochemistry Standardization Program - Establishment & Launch

NIH RePORTER · NIH · R44 · $1,101,356 · view on reporter.nih.gov ↗

Abstract

The overarching goal of this project is to change laboratory practice in the Clinical Immunohistochemistry (IHC) laboratory. IHC is the only clinical laboratory discipline without reference standards and traceable units of measure. This is despite the fact IHC is a major testing format in surgical pathology; a typical hospital IHC lab has a test menu of approximately 200 different tests. As a result, IHC analytic error rates range from 10 – 30% as compared to <1% for other types of clinical laboratory testing. These errors affect both predictive markers (HER2, PD-L1) as well as diagnostic markers (e.g., TTF-1, p53). From the 1950's to the 1970's, the field of Clinical Chemistry broadly adopted these higher standards of practice and error rates plummeted. This project is for the purpose of demonstrating the same benefit in Clinical IHC. This Applicant is uniquely qualified after having surmounted an important technical hurdle. Boston Cell Standards developed the first IHC calibrators with analyte concentrations traceable to a recognized standard - NIST Standard Reference Material 1934. The two Specific Aims of this project are: (1) Identify quantitative calibration ranges for accurate Clinical IHC testing, and (2) measure the benefit that calibrators offer towards reporting accurate test results. These will be the first studies correlating analytic sensitivity with diagnostic sensitivity and specificity. Namely, how many molecules per cell (of the target analyte) must the assay be capable of detecting in order to produce a diagnostically accurate test result? This is important even for qualitative tests that are reported as positive/negative, which are common in IHC. This analysis, while common in other fields of laboratory testing, is new to IHC. The experimental study design uses a Clinical IHC laboratory survey tool comprising a tissue microarray (TMA) and IHC calibrators. The TMA generates diagnostic sensitivity and specificity data while calibrators generate analytic sensitivity data. This project initiates a novel consortium that includes Boston Cell Standards, international IHC proficiency testing agencies, and academia. Although there is precedent in creating high-impact standardization programs for Clinical Chemistry testing, such an organization is unprecedented for IHC. The goal is to create and launch a National Immunohistochemistry Standardization Program, to oversee and execute data-driven studies for integrating reference standards to IHC. The consortium members are active partners in experimental design, execution, and data interpretation. The proposed clinical trial format has already been successfully tested and published with some of the consortium partners.

Key facts

NIH application ID
10383397
Project number
1R44CA268484-01
Recipient
BOSTON CELL STANDARDS INC
Principal Investigator
Steven A Bogen
Activity code
R44
Funding institute
NIH
Fiscal year
2021
Award amount
$1,101,356
Award type
1
Project period
2021-09-21 → 2023-08-31