# Knotless Soft Tissue Augments for Improving Arthroscopic Rotator Cuff Repair Biomechanics

> **NIH NIH R43** · ASANTE BIO LLC · 2022 · $247,705

## Abstract

Knotless Soft Tissue Augments for Improving Arthroscopic Rotator Cuff Repair Biomechanics
 Load sharing and reinforcing soft tissue with knotless suture augments present a disruptive and
innovative technology to managing the surgical care of rotator cuff injuries and prospectively other injuries
where suture pull-through can have catastrophic effects. This phase I SBIR proposal endeavors to develop a
new field of study and redefine clinical practice via innovative soft tissue augment (STA) implants to improve
suture load distribution and tissue healing in rotator cuff repair (RCR) and related surgeries. The significance of
this project is medical engineering of strong, reinforcing, resorbable polymeric implants that will allow for
studying joint repair stability, understanding the causes/mechanisms of RCR failure, and ultimately preventing
these failures via a commercial product. Central to the NIAMS mission, tendon re-tear following surgical RCR
occurs in as high as 20-45% or more of primary repairs. This failure rate is an unacceptable fact, given that
800,000 RCR procedures are performed annually in the U.S. alone. In addition, rotator cuff injuries do not heal
well on their own, cause limited mobility, persistent pain, and impact return to activity.
 Current RCR surgical strategies involve extensive use of sutures passed arthroscopically to provide
tissue approximation. Unfortunately, suture-only repair commonly fails and instead leads to mechanically weak
scar tissue formation, prone to subsequent failure, pain, and disability. The tendon-to-suture interface is
believed to be the most common RCR failure mode. It is hypothesized that RCR failure occurs via gap
formation at the enthesis, primarily due to elongation or suture cut-through at the suture-tendon interface. STAs
we are engineering will distribute and share the mechanical load and prevent suture-to-tendon failure as an
innovative approach to significantly improve RCR. Hypothesis: If Soft Tissue Augments (STAs) improve tissue
repair biomechanics by reinforcing standard suture-based rotator cuff repair, then type 2 retears will be
significantly reduced.
 Aim 1: To determine and optimize soft tissue augment biomechanical properties. Approach: 3D
printed tendon augments implants will be produced from PDO and UHMWPE from the two STA designs
(round and tab shaped) for surgeon assessment and simulated use. The tendon suture augments will be tested in
cadavers for validating arthroscopic delivery. In addition, STAs surgically placed on the repaired tendons will
be tested for biomechanical performance in pull-to-failure and cyclic testing relative to repair with only sutures
(the standard of care).
 Aim 2: To determine soft tissue augment stability and biocompatibility. Approach: STA will also
be assessed for biocompatibility per ISO 10993-6. The STA implant stability will also be assessed per ASTM
1635-16 standard testing to determine the resorption rate of the soft tissue augments.

## Key facts

- **NIH application ID:** 10546104
- **Project number:** 1R43AR081735-01
- **Recipient organization:** ASANTE BIO LLC
- **Principal Investigator:** Michael Paul Francis
- **Activity code:** R43 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 2022
- **Award amount:** $247,705
- **Award type:** 1
- **Project period:** 2022-09-23 → 2024-03-31

## Primary source

NIH RePORTER: https://reporter.nih.gov/project-details/10546104

## Citation

> US National Institutes of Health, RePORTER application 10546104, Knotless Soft Tissue Augments for Improving Arthroscopic Rotator Cuff Repair Biomechanics (1R43AR081735-01). Retrieved via AI Analytics 2026-05-28 from https://api.ai-analytics.org/grant/nih/10546104. Licensed CC0.

---

*[NIH grants dataset](/datasets/nih-grants) · CC0 1.0*