# Improving the Speed of Galvo-Scanners

> **NIH NIH R21** · CORNELL UNIVERSITY · 2024 · $328,000

## Abstract

Abstract
 Optical methods provide high-resolution, non-invasive measurement of neural function, ranging
from single neurons to entire populations, in the intact brain. Nevertheless, limited penetration depth,
spatial scale and temporal resolution remain the main challenges for optical imaging. Laser scanning
multiphoton microscopy is the main technology used for cellular-level imaging in scattering brains.
Because of the point scanning nature of laser scanning microscopy, the speed of the optical scanner
determines the imaging speed, even when there is sufficient signal strength for fast imaging. For
inertially dependent scanners like galvanometers and resonant scanners, increasing the scan speed
requires decreasing the moment of inertia of the dynamic component, while the need for high spatial
resolution requires increasing the aperture of the scan mirror. The balancing of these two conflicting
requirements has limited commercially available galvanometer scanners at approximately the same
speed for the last 30 to 40 years. The focus of this proposal is to demonstrate a new concept that will
improve the scan speed of galvanometer-based optical scanners (galvo-scanners), and increasing the
imaging speed of laser scanning microscopy. The proposed new concept leverages the uniaxial nature
of galvanometer scanning, i.e., a galvo-scanner scans one spatial dimension only, which leaves the
orthogonal dimension free for manipulation. By using a cylindrical lens to focus the beam onto the scan
mirror along the axial direction of the galvanometer (i.e., the non-scanning direction) and another
cylindrical lens to recollimate the beam after scanning, we can reduce the size of the scan mirror
dramatically along the non-scanning direction. The resulting reduction in mirror mass and moment of
inertia will increase the scan speed without reducing the scanned field-of-view and spatial resolution.
The proposed program dovetails with our effort in developing technologies for brain imaging. We will
test and validate the new scanners in laser scanning 2-photon and 3-photon microscopes for in vivo
recording of mouse brain activity. The successful completion of this program will create new optical
scanners that will improve the imaging speed of all galvo-based laser scanning microscopes. Since the
design, test and demonstration are all based on typical multiphoton microscopes, the new concept can
be immediately translated to other research labs. Furthermore, we will work with commercial instrument
builders to accelerate the research and adoption of the technology developed in this program.

## Key facts

- **NIH application ID:** 10846582
- **Project number:** 5R21EY034809-02
- **Recipient organization:** CORNELL UNIVERSITY
- **Principal Investigator:** CHRIS XU
- **Activity code:** R21 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 2024
- **Award amount:** $328,000
- **Award type:** 5
- **Project period:** 2023-06-01 → 2026-05-31

## Primary source

NIH RePORTER: https://reporter.nih.gov/project-details/10846582

## Citation

> US National Institutes of Health, RePORTER application 10846582, Improving the Speed of Galvo-Scanners (5R21EY034809-02). Retrieved via AI Analytics 2026-05-30 from https://api.ai-analytics.org/grant/nih/10846582. Licensed CC0.

---

*[NIH grants dataset](/datasets/nih-grants) · CC0 1.0*