# Photo-hyperpolarized 13C MRI

> **NIH NIH R01** · ADAMAS NANOTECHNOLOGIES, INC. · 2024 · $333,773

## Abstract

Summary. High resolution imaging in deep tissue (> 1 cm) environments can address a swathe of funda-
mental and applied problems in the elucidation of mechanisms of disease origin and progression. While fluores-
cence imaging is a workhorse technique for the cellular imaging of biological molecular markers, it suffers from
light scattering, and aberration distortions at tissue depths >1 mm. On the opposite end of the spectrum, mag-
netic resonance imaging (MRI) is a well-established and broadly employed pre-clinical and clinical imaging
method that has no practical limitations with respect to tissue depth, but it suffers from low resolution. In this
project we will innovate a new class of hyperpolarized 13C nanoparticle probes that can serve as efficient deep
tissue markers in MRI. Our central idea is to dramatically boost 13C NMR signal by means of (i) optical hyperpo-
larization that can be carried out at low magnetic fields and (ii) significant extension of 13C coherence times.
Specifically, we propose to develop MRI probes based on fluorescent nanodiamonds (FNDs) endowed with
nitrogen-vacancy (NV) centers. The electronic spins associated with NVs can be optically “hyperpolarized” and
that polarization to be effectively transferred to the diamond 13C nuclear spins, resulting in NMR signal enhance-
ment over three orders of magnitude vs. 13C thermal polarization at the fields of clinical MRI. In conjunction, by
implementing effective decoupling schemes we propose significantly extend the 13C spin coherences to be able
to interrogate them for second-long periods. The latter yields enormous signal gains, a multiplicative factor of
another 103- fold. Combining the gains due to hyperpolarization and spin coherence extensions permits a total
signal gain of ca. 106 for MRI, and will enable a significant improvement in spatial resolution. Moreover, since
the polarization is optically generated, this 13C photo-MRI (PMRI), can be carried out at low-field at a much lower
cost vs. conventional MRI infrastructure. In our method the spin polarization is regenerated optically, allowing for
acquiring MRI data repeatedly and enabling longitudinal studies. Furthermore, the FND particles are inherently
biocompatible, and their surfaces are amenable to a versatile set of targeting ligands. With this basis, we propose
to develop targetable fluorescent nanoparticle MRI probes that can be imaged with high fidelity with resolution
better than 20 um in deep tissue (>1 cm) settings. In addition to being bright MRI agents, the particles are also
bright fluorescent providing an option for a cross-examination of the agent biodistribution in histopathological
analysis. In order to realize the prospects of this novel technology, we propose to further develop the hyperpo-
larization and MR imaging methodologies, as well as boost hyperpolarizability of nanosized particles by optimiz-
ing their structure through synthesis and processing developments. We aim at transferring the...

## Key facts

- **NIH application ID:** 10922686
- **Project number:** 5R01GM143626-03
- **Recipient organization:** ADAMAS NANOTECHNOLOGIES, INC.
- **Principal Investigator:** Ashok Ajoy
- **Activity code:** R01 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 2024
- **Award amount:** $333,773
- **Award type:** 5
- **Project period:** 2022-09-28 → 2026-07-31

## Primary source

NIH RePORTER: https://reporter.nih.gov/project-details/10922686

## Citation

> US National Institutes of Health, RePORTER application 10922686, Photo-hyperpolarized 13C MRI (5R01GM143626-03). Retrieved via AI Analytics 2026-05-23 from https://api.ai-analytics.org/grant/nih/10922686. Licensed CC0.

---

*[NIH grants dataset](/datasets/nih-grants) · CC0 1.0*
