Advancing and calibrating anisotropic diffusion MR imaging brain connectome with Taxon brain network diffusion phantoms

NIH RePORTER · NIH · R44 · $621,536 · view on reporter.nih.gov ↗

Abstract

There is a critical gap in the reliability of anisotropic diffusion magnetic resonance imaging (AdMRI). This gap can be filled by using a ground truth measurement capability that allows for the necessary parametric control of water filled geometries of tubes at the micron scale that can produce paths representative of the millions of axons across centimeters in brain tract trajectories. Diffusion Tensor Imaging (DTI) publications report clinically significant systematic error that confounds accurate quantitative assessments across instruments and time. Reference phantoms that provide exact error metrics will advance MRI biophysics science and clinical quantitative accuracy. Correction algorithms using reference data can reduce systematic measurement error, enabling accurate reproducible measurement and provide cross scanner norms for AdMRI pathology. This project will deliver the first viable AdMRI phantom “ground truth” using ‘Taxons™’ (textile axon shaped nanotubes), invented by this team, and apply advanced bi-component polymer nanoscale production methods to create structures matched to human tissue histology. In doing this we will deliver axon scale taxons at 800 nanometer diameter, with a packing density of one million taxons per mm2, matched to actual human corpus callosum axon measurements. In Phase I we proposed and delivered taxons with 12 micron inner diameter tubes with a packing density of 1241 per mm2 that could be filled with water and produce FA measurement in the human tissue range. We actually “over- delivered”, exceeding a packing density of 1,000,000 per mm2 covering the human axonal tissue range. We can now precisely parametrically control the diameters, packing density, restricted/hindered, and isotropic water fractions to test and improve leading compartmental models of diffusion. We created a fasciculus routing machine that can, at viable cost, create human scale fasciculus routes matched to human tissue, such as the optic system eye to LGN, of 20 million routed taxons. The 1 to 1 scale taxonal network phantoms quantify dMRI measurement accuracy for each taxon path with 100 micron path precision along the trajectory. We scanned the phase I phantoms at ten sites. We established in empirical studies that there is substantial systematic, cross instrument and measurement error (e.g., 5x the TBI effect size), that the error is stable, and can be corrected for (removed 94% of systematic error). Phase II of this project will: 1) provide the first AdMRI phantom for ground truth measurement to quantify dMRI biophysics, spatial homogeneity, and routing precision; 2) provide fully automated quantification of accuracy and repeatability of measurement; 3) assess AdMRI precision of 20+ sites, quantifying measurement error at 1.5, 3, 7, 9.4 and 14T field strength; and4) develop a set of routing phantoms (Eye>LGN> V1, spinal cord and cortical tracts). These phantoms and/or subcomponents will be measured with non-MRI methods (confocal & el...

Key facts

NIH application ID
9893037
Project number
5R44NS103729-03
Recipient
PSYCHOLOGY SOFTWARE TOOLS, INC.
Principal Investigator
Anthony P Zuccolotto
Activity code
R44
Funding institute
NIH
Fiscal year
2020
Award amount
$621,536
Award type
5
Project period
2017-09-01 → 2022-08-31