# A Fluorescent Sensor of Membrane Tension

> **NIH NIH R21** · UNIV OF MARYLAND, COLLEGE PARK · 2020 · $244,309

## Abstract

Abstract Cell mechanics has been increasingly found to play a significant role in all aspects of cell function,
including signaling, migration, differentiation, and survival. The altered state of stress-bearing elements in cells
occurs during malignant transformation and metastasis, in hemolytic anemia, nephrotic syndrome, and
muscular dystrophy. The distribution of stress and strain in cells is complex and the associated feedback
mechanisms are not well understood. Progress in single-molecule biophysics and synthetic biology led to the
development of FRET-based molecular sensor domains reporting on local forces in the cytoskeleton and
ECM. However, there is essentially no information about tension in the plasma membrane and no principle for
its measurement has been proposed to date. Our recent study of the mechanosensitive channel blocker
Grammostola mechanotoxin (GsMTx4) indicated that the peptide binds to the membrane but undergoes a
sharp redistribution between the ‘shallow’ and ‘deep’ binding modes in a narrow range of membrane tensions
near the resting tension of the membrane. The change in membrane area contributed by the inserted peptide
produces a ‘tension clamp’ effect in one leaflet and redistribution of tension to the other. In this proposal we
will explore this principle of the tension-dependent transition of this conical amphipathic molecule in the
membrane to create a set of fluorescent tension reporters based on the GsMTx4 peptide scaffold. Aim 1 will
include computational design of a synthetic sensor peptide equipped with an environmentally-sensitive
fluorescent sidechain in a specific location and experimental calibration of its fluorescent signal in model
membranes. The tests will include measurements of fluorescence as a function of lateral pressure/tension in
Langmuir monolayers, pipette aspiration experiments with giant unilamellar vesicles and cytoskeleton-
depleted membrane blebs, and osmotic shock of liposomes in stopped-flow experiments. These tests will
enable optimization of peptide sensitivity in specific tension ranges. Aim 2 will validate the use of GsMTx4-
based sensors in live cells using a range of mechanical stimuli. Membrane stress in cells will be generated
using blunt probes, stretch on an elastic support, osmotic shock, fluid shear stress, and by motor proteins as
cells adhere and move on substrates. We will look for heterogeneities in GsMTx4 surface distribution, and
global and local responses to tension application and release. We will determine if stressed (brighter) or
protected regions co-localize with ordered domains, focal adhesions, processes and invaginations, or
mechanosensory complexes. Fluorescent signals of the surface-bound tension sensors will be correlated with
activities of mechanosensitive channels (Piezo 1) under various mechanical stimuli. We will compare the
kinetics of the membrane tension changes to changes in cytoskeletal stress using our FRET based fluorescent
force sensor cpstFRET. ...

## Key facts

- **NIH application ID:** 9958910
- **Project number:** 1R21GM137274-01
- **Recipient organization:** UNIV OF MARYLAND, COLLEGE PARK
- **Principal Investigator:** SERGEI I SUKHAREV
- **Activity code:** R21 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 2020
- **Award amount:** $244,309
- **Award type:** 1
- **Project period:** 2020-05-01 → 2022-04-30

## Primary source

NIH RePORTER: https://reporter.nih.gov/project-details/9958910

## Citation

> US National Institutes of Health, RePORTER application 9958910, A Fluorescent Sensor of Membrane Tension (1R21GM137274-01). Retrieved via AI Analytics 2026-05-23 from https://api.ai-analytics.org/grant/nih/9958910. Licensed CC0.

---