Improved Motion Robust MRI of Children

NIH RePORTER · NIH · R01 · $576,482 · view on reporter.nih.gov ↗

Abstract

Project Summary Magnetic resonance imaging (MRI) is critically important for pediatric care. However, patient motion significantly limits our ability to produce high-quality images in young children who may be unable to respond well to verbal instructions and who have difficulty remaining still inside the scanner. Head motion during MRI disrupts spatial encoding and leads to data loss, generating a range of artifacts in the images, which hinders diagnostic utility. Thus, sedation and anesthesia are routinely used in pediatric populations; however, these practices are associated with severe adverse events and are extremely time-consuming and costly to administer. Unfortunately, current state-of-the-art motion compensation technologies are not fast or accurate enough to adequately compensate for large and frequent head movements in uncooperative children, or require external hardware, which is far from ideal for clinical workflow. Under the previous grant period, we made significant progress towards our overarching goal of improved motion-robust pediatric MRI by successfully developing a new markerless motion tracking approach utilizing free induction decay (FID) navigators and novel algorithms to generate diagnostic images from small periods of motion-free time. The goal of the research proposed under this renewed application to the NIH is two-fold: 1) to continue to develop and refine novel markerless technologies for motion measurement and correction to enable high-quality MRI in the presence of large, frequent motion and 2) to evaluate these technologies for improving the quality and success rate of pediatric MRI without the use of sedation and anesthesia. We hypothesize that improving the accuracy of FID navigator motion measurements, and the extent and speed of our correction algorithms, will successfully compensate for sources of persistent artifacts in the images. To achieve these ambitious goals, we propose to undertake the following Specific Aims over the 5-year period of requested support: 1) develop and evaluate an extended model that can, for the first time, simultaneously measure head motion and induced magnetic field changes using FID navigators; 2) develop and evaluate a novel self-navigated 3D radial acquisition with augmented reconstruction for retrospective correction of motion, and induced magnetic field and coil sensitivity variations; 3) develop and evaluate prospective motion correction and dynamic shimming utilizing real-time motion and field measurements to produce artifact-free images; and 4) apply and evaluate these highly innovative motion compensation techniques for imaging 0–8 year old patients without the use of sedation. The motion-robust imaging technologies proposed in this application can be easily deployed in clinical settings with widely-available, standard MRI hardware, and are therefore expected to have rapid translational impact for the countless pediatric diseases and disorders presently evaluated by MRI. Th...

Key facts

NIH application ID
9993667
Project number
2R01EB019483-05A1
Recipient
BOSTON CHILDREN'S HOSPITAL
Principal Investigator
SIMON K WARFIELD
Activity code
R01
Funding institute
NIH
Fiscal year
2020
Award amount
$576,482
Award type
2
Project period
2015-07-01 → 2025-03-31