# FALL OF ROOF OR BACK
> MSHA accident `220000270033` · 01/24/2000 · Blue Mountain Energy Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Deseret Generation & Transmission Co-operative
- **Operator:** Blue Mountain Energy Inc
- **Mine:** [0503505](https://api.ai-analytics.org/mine/0503505)
## Narrative

A ROOF FALL HAS OCCURRED IN #2 ENTRY XCUT 4 OF 1 LEFT SECTION. THE ROOF FALL OCCURRED BETWEEN 1-20 TO 1-24-2000. THE ROOF FALL MEASURED 22' IN WIDTH AND 20' IN LENGTH, APPROX. 10-12' HIGH. THE ROOF HAD BEEN BOLTED WITH 7' RESIN BOLTS ON 5' CENTERS.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*