# FALL OF ROOF OR BACK
> MSHA accident `220000280042` · 01/23/2000 · Wayne Processing Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Rex  Fought
- **Operator:** Wayne Processing Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED 1-23 AT 9:05PM ON D-4 PANEL NO.36 BREAK 2-3 X-CUT AT #3 INTERSECTION INTO THE 3-4 CROSSCUT. THE FALL WAS 60 FT LONG BY 18 FT WIDE BY 14 FT HIGH. THE FALL CO NTAINED 6 FT RESIN BOLTS AND 2 14 FT CABLE BOLTS. APPROACHES HAVE BEEN CRIBBED AND DANGERED OFF.THE FALL WILL NOT BE CLEANED UP.

---