THE MINE EXPERIENCED AN UNPLANNED ROOF FALL AT XCUT 10, NO 2 2 ENTRY IN THE 16 LEFT PANEL. THE AREA HAD A FAULT PASSING THROUGH THIS INTERSECTIONTHE INTERSECTION HAD BEEN SUPPORTED WITH 6 FT RESIN BOLTS, STEEL MATS, WIRE MESH, AND SUPPLEMENTED WITH 10 FT CABLE BOLTS, TIMBERS, PROPSETTERS, AND CRIBS. THE FALL WAS ABOVE THE BOLTS.