THIS IS AN AMMENDED COPY THIS FALL WAS CRIBBED AND TIMBERED OFF INT HE #4 ENTRY. ALSO NO.3 ENTRY WAS STOPPED FROM ADVANCING ON 2-2-00 AFTER THEY WERE BOLTED. THE TEST HOLES SHOWED CRACKS IN TH E ROOF THERE FORE THE ROOF WAS ALLOWED TO FALL. THIS WAS NOT AN UNINTENIONAL ROOF FALL. FALL IS APP. 140 FT OUTBY WORKING FACES.