ROOF FALL IN MAINS #2 ENTRY FROM #7 TO C6. C7 TO C6 WAS ALREADY CRIBBED OFF, XC7 WAS INACCESSIBLE. XC6 WAS PRIMARY ESCAPEWAY LEADING TO 1ST LEFT PANEL XC6 FALL AREA WAS 18' LONG BY 20' WIDE BY 2-7' HIGH FROM GROUND, XC7 TO XC6 42' LONG 2' TO 8' HIGH 18' WIDE. IT WILL BE RESUPPORTED AND TRAVEL OPENED BACK UP. AREAS WILL NOT BE CRIBBED AND DANGERED OFF.