← MSHA accidents

FALL OF ROOF OR BACK

220000830047 · 03/16/2000 · Wayne Processing Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Rex Fought
Operator
Wayne Processing Inc
Mine
4608622

Narrative

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED 3-16-2000 AT 1:15AM IN THE TRACK ENTRY(NO. 3 ENTRY) 4 BREAKS INBY THE PIT MOUTH. THE FALL WAS 16 FT WIDE X 25 FT LONG X 7 FT HIGH. THE AREA CONTAINED 6 FT RESIN TENSION BOLTS & WAS DEVELOPED AUGUST 1997. THE FALL WILL BE RE-SUPPORTED AND CLEANED UP.

Source

Authoritative
MSHA Open Government Data
Machine