# FALL OF ROOF OR BACK
> MSHA accident `220000830048` · 03/11/2000 · Wayne Processing Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Rex  Fought
- **Operator:** Wayne Processing Inc
- **Mine:** [4608622](https://api.ai-analytics.org/mine/4608622)
## Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED ON C-1 PANEL, NO.5 ENTRY 4-WAY INTERSECTION AT SPAD 4240. THE FALL WAS APPROX 18'W X 40'L X 12'H. THE FALL WILL BE CLEANED UP. CROSS BARS WERE ADDED AT APPR OACHES FOR ADDL SUPPORT AND THE CAVITY WILL BE SUPPORTED AS PER THE ROOF CONTROL PLAN. THE FALL CINTAINED 6' RESIN BOLTS AND WAS IN THE LAST OPEN BREAK IN THE BELT ENTRY ON THE 002-0 MMU.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*