A ROOF FALL WAS DISCOVERED AT NO.5 BREAK INTERSECTION (SPAD NO.23) NO.2 ENTRY INBY THE PIT OPENING. THE FALL WAS APPROX 16'W X 20'L X 10'H. THE FALL CONTAINED 6' RESIN TENSION BOLTS. THE FALL WAS DANGERED OFF AND WILL NOT BE CLEANED UP AT THIS TIME. THE AREA WAS DEVELOPED AUGUST 1997.