# FALL OF ROOF OR BACK
> MSHA accident `220000840015` · 03/22/2000 · Canyon Fuel Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Arch Resources Inc
- **Operator:** Canyon Fuel Company LLC
- **Mine:** [4201566](https://api.ai-analytics.org/mine/4201566)
## Narrative

WEEKLY EXAMINER DISCOVERED A ROOF FALL IN THE NO. 1 ENTRY OF 14LTG AT X-CUT 26-27. THE FALL MEASURED APPROXIMATELY 18'WX5'HX40'L. THE AREA HAD BEEN BOLTED WITH 6' RESIN BOLTS, SUPPLEMENTED W ITH WIRE MESH AND WOODEN PROSETTERS. THIS AREA IS UNDER A PANEL EDGE IN MIN 1 ABOVE.

---