THE FALL OCCURRED IN THE CROSSCUT LOCATED BETWEEN THE NO.2 & 3 ENTRIES AT SURVEY STATION 804. PILLARS WERE BEING PULLED THE FALL CAUGHT 2 MOBILE ROOF SUPPORTS LOCATED IN THE CROSSCUT THE PIL LAR FALL WAS THE WIDTH OF THE ENTRY 20' & APPEARS TO BE 20+FT HIGHT THERE WERE NO INJURIES